Contentful ID
269627974
Japan Atomic Energy Agency (JAEA)
Contentful ID
1d678c9d-a0d1-2a2d-c26c-da81e323604c-draft
Company Values
Entity Description
A Japanese Administrative Institution and Japan's comprehensive nuclear energy research and development institute
Entity Name
Japan Atomic Energy Agency (JAEA)
Focus Areas
General - Organization
Entity Type
Other
Is LCRI Company?
No
Technology Areas
Technology Description
GTHTR300 is a helium-cooled, graphite-moderated thermal spectrum, prismatic high-temperature gas-cooled reactor with 14% enriched uranium-based TRISO fuel with flexible industrial/electricity generation applications. It provides a maximum of 600 MWt power and 100-300 MWe, depending on its application.
Technology Name
Gas Turbine High Temperature Reactor, 300 MW (GTHTR300)
French Alternative Energies and Atomic Energy Commission (CEA)
Contentful ID
1610bac6-78e1-41a5-b25c-299c7e0ffd39-draft
Company Values
Entity Description
A French public, government-funded research organization that conducts research and development in the areas of defense and security, low-carbon energies, industrial technologies, and the physical and life sciences
Entity Name
French Alternative Energies and Atomic Energy Commission (CEA)
Focus Areas
General - Organization
Entity Type
Other
Group/Division/Lab name
Nuclear Energy
Is LCRI Company?
No
Technology Areas
Technology Description
ASTRID is a sodium-cooled, pool-type fast spectrum reactor fueled by mixed oxide (MOX) fuel with a capacity of 1500 MWt/600 MWe. As an industrial demonstration reactor, ASTRID will be used to optimize the design of future commercial reactors under the umbrella of the Generation IV forum (GIF).
Technology Name
Advanced Sodium Technological Reactor for Industrial Demonstration (ASTRID)
Argonne National Laboratory
Contentful ID
179502e2-be96-67f9-0cd6-b5bbc6ae887d-draft
Company Values
Entity Description
A science and engineering research laboratory operated by the University of Chicago Argonne LLC for the US Department of Energy
Entity Name
Argonne National Laboratory
Focus Areas
General - Organization
Entity Type
National Lab
Group/Division/Lab name
Nuclear Engineering Division
Is LCRI Company?
No
Technology Areas
Technology Description
As part of the Heavy Liquid Metal Coolant (HLMC) research initiative, Argonne National Laboratory (ANL) has developed multiple multiple advanced reactor technologies, including the Secure Transportable Autonomous Reactor with Liquid Metal (STAR-LM) and the Small Secure Transportable Autonomous Reactor (SSTAR). SUPERSTAR, a lead-cooled, pool-type fast spectrum reactor is the most recent HLMC research initiative design. It has a capacity of 300 MWt/120 MWe is designed for electricity generation on the export market.
Technology Name
Sustainable Proliferation-resistance Enhanced Refined Secure Transportable Autonomous Reactor (SUPERSTAR)
Atomic Energy of Canada Ltd (AECL)
Contentful ID
069910a9-efe5-f9f9-0fa1-b1ac4b60691c-draft
Company Values
Entity Description
AECL is a Canadian federal crown corporation and Canada's largest nuclear science and technology laboratory, well known for developing the CANDU reactor technology.
Entity Name
Atomic Energy of Canada Ltd (AECL)
Focus Areas
General - Organization
Entity Type
Other
Is LCRI Company?
No
Technology Description
Fueled by plutonium and thorium, this pressure tube-type SCWR operates in the thermal neutron spectrum at a high pressure of 25 MPa. It is moderated by heavy water and cooled by supercritical light water, utilizes a direct steam cycle power conversion system, and has a capacity of 2540 MWt/1200 MWe. AECL is also developing a small, modular version of its SCWR called the Supersafe Reactor (SSR).
Technology Name
Candian Supercritical Water Reactor (Canadian SCWR)
Atomos Nuclear and Space
Contentful ID
0e5a84d3-90bb-ed11-4fde-0eaff2c75e18-draft
Company Values
Entity Description
Atomos is designing and space-rating nuclear fission reactors for long-duration and highly-demanding space applications. The company was a finalist in the iTech Energy Cycle competition hosted by NASA and the US Department of Energy's Advanced Research Projects Agency-Energy.
Entity Name
Atomos Nuclear and Space
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
Building an optimized in-space transportation network powered by small modular reactors, beginning with nuclear-powered space tugs for precision orbital insertion of spacecraft and cargo hauling.
Moltex Energy, LLP
Contentful ID
d20ffc5b-9b84-5717-d550-e7734ec00dde-draft
Company Values
Entity Description
A UK-based company focused on the development and commercialization of their modular Stable Salt Reactor, a molten salt reactor variant with liquid fuel contained in conventional, static fuel assemblies
Entity Name
Moltex Energy, LLP
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The SSR is a zirconium and sodium fluoride salts-cooled, graphite-moderated thermal spectrum molten salt reactor. 8 37.5 MWe modules form a standard 750 MWt/300MWe unit. The static form of the liquid fuel salt eliminates many of the technical hurdles associated with mobile, liquid fuels typical to molten salt reactors; fuel assemblies are designed for compatibility with existing IAEA Safeguard procedures
Technology Name
Stable Salt Reactor (SSR)
TerraPower, LLC
Contentful ID
7d5185ab-30e4-7da2-977a-01f032207641-draft
Company Values
Entity Description
TerraPower is a nuclear energy technology company founded to develop and commercializes its Traveling Wave Reactor and Molten Chloride Fast Reactor. Bill Gates is the company's co-founder, chairman of the board, and primary financial backer. In January 2016, TerraPower received a 5-year, $40 million cost-share award from the US Department of Energy for the continued research and development of its Molten Chloride Fast Reactor.
Entity Name
TerraPower, LLC
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The MCFR is a chloride salt-cooled, liquid-fueled fast spectrum molten salt reactor operating on a U-Pu fuel cycle. This breed-and-burn concept utilizes depleted or unenriched (natural) uranium as makeup fuel.
Technology Name
Molten Chloride Fast Reactor (MCFR)
Terrestrial Energy Inc.
Contentful ID
feef759b-a2df-a264-f9bc-0e5e713dc714-draft
Company Values
Entity Description
Terrestrial Energy was founded to develop and commercialize its Integral Molten Salt Reactor (IMSR). In 2017, the IMSR was the first advanced reactor to complete Phase 1 of the Canadian Nuclear Safety Commission's Pre-Licensing Vendor Design Review.
Entity Name
Terrestrial Energy Inc.
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The IMSR is a fluoride salt-cooled, graphite-moderated, liquid-fueled thermal spectrum reactor based heavily on Oak Ridge National Labs' Denatured Molten Salt Reactor. The 400 MWt/190MWe reactor is designed to operate for 7 years with online refueling, utilizing 5% (or lower) enriched uranium as both startup and makeup fuel. The integral reactor vessel, which contains all primary systems, doubles as intermediate-term containment and is designed to remained sealed during operation.
Technology Name
Integral Molten Salt Reactor (IMSR)
Commonwealth Fusion Systems
Contentful ID
f1c797fd-2839-1ece-15d1-09a5cafa7f00-draft
Company Values
Entity Description
A spinoff from MIT's Plasma Science and Fusion Center, Commonwealth plans to build compact fusion power plants utilizing advanced magnet technologies, based on the tokamak approach to confining fusion-grade plasmas with strong magnetic fields.
Entity Name
Commonwealth Fusion Systems
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
CFS plans to engineer Rare-Earth Barium Copper Oxide (REBCO), a new superconductor technology, into high-field magnets, which enables much smaller tokamak fusion systems.
Oklo (formerly UPower)
Contentful ID
2653aaf0-76da-24b3-319d-2f248f815d4f-draft
Company Values
Entity Description
Y Combinator-hosted Oklo is a nuclear energy startup company founded by graduates of MIT's Nuclear Engineering department to develop and commercialize a container-sized MW-scale "nuclear generator"
Entity Name
Oklo (formerly UPower)
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
Oklo's reactor is a liquid metal-cooled, fast spectrum reactor utilizing a metallic fuel. It is designed to be small, portable, and suitable for remote deployment.