Contentful ID
269627974

Kurchatov Institute

Contentful ID
97e1cef2-2da5-9367-1dae-563e3ab66b8e-draft
Company Values
Entity Description
Russia's National Research Center, also known as the Kurchatov Institute, is a leading nuclear research and development facility.
Entity Name
Kurchatov Institute
Focus Areas
Entity Type
National Lab
Is LCRI Company?
No
Technology Description
Construction of the nuclear fission-fusion hybrid reactor is under construction, with start-up scheduled in 2020. A molten salt blanket will capture neutrons produced in a small tokamak fusion reactor to drive a fission reaction that relies on the thorium fuel cycle.
Technology Name
T-15MD

Los Alamos National Laboratory

Contentful ID
f1a40c2f-36d0-f5eb-1dc1-bd17fd839fc2-draft
Entity Description
A United States Department of Energy national laboratory located in New Mexico.
Entity Name
Los Alamos National Laboratory
Focus Areas
Entity Type
National Lab
Is LCRI Company?
No
Technology Description
A 5 MWt/2 MWe heat pipe reactor for "plug-and-go" power applications in remote installations and communities. The design is capable of rapid installation and shutdown and largely autonomous operation for 5 years without refueling. MegaPower is fueled by high-assay low enriched uranium oxide.
Technology Name
MegaPower/Special Purpose Reactor

X-Energy

Contentful ID
806b7d1a-b46b-515a-7b7b-4929cad1f7fd-draft
Company Values
Entity Description
X-Energy was formed to develop and commercialize its pebble bed high temperature gas-cooled reactor design. The company is also developing and has plans to manufacture TRISO fuel pebbles.
Entity Name
X-Energy
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
The X-battery is a gas-cooled pebble bed reactor fueled by high assay LEU fuel particles, capable of autonomous operation. The 10 MWt reactor is road-transportable and can be configured to provide combined heat and power.
Technology Name
X-battery / Xe-100 MICRO reactor

Seaborg Technologies

Contentful ID
2771f9cd-7832-e746-ab4b-16e8f8fa650b-draft
Company Values
Entity Description
Seaborg is a Danish company developing a thorium MSR concept.
Entity Name
Seaborg Technologies
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
The CUBE is a 150 MWt/100 MWe liquid-fueled, single fluid, thermal spectrum molten salt reactor design fueled by a combination of thorium and spent fuel from LWRs.
Technology Name
Seaborg CUBE (Compact Used fuel BurnEr) reactor

LeadCold

Contentful ID
b36a9f13-4f2c-c693-1392-e2418f790368-draft
Company Values
Entity Description
A spin-off company from the Royal Institute of Technology (KTH) in Stockholm, LeadCold is developing a small, lead-cooled reactor for remote applications, especially in the Canadian Arctic.
Entity Name
LeadCold
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
SEALER is an 8 MWt/3 MWe lead-cooled fast reactor design for remote applications. SEALER is fueled by high-assay low enriched uranium oxide fuel, and operates for 10-30 years without on-site refueling. LeadCold developed a corrosion-resistant aluminum alloyed steel for use in the reactor.
Technology Name
Swedish Advanced Lead Reactor (SEALER)

Westinghouse Electric Company, LLC

Contentful ID
2e676575-4bde-0b4c-d1ad-382d4c41216a-draft
Company Values
Entity Description
Westinghouse Electric is a nuclear technology company that offers nuclear plant design, fuel service and maintenance and control systems solutions.
Entity Name
Westinghouse Electric Company, LLC
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
Scalable, heat pipe-cooled reactor design producing combined heat and power of 0.2-25 MWe for decentralized and/or remote generation markets. The factory-built and assembled eVinci has inherent load following capabilities, rapid on-site installation potential, and infrequent refueling needs.
Technology Name
eVinci Micro Reactor

HolosGen

Contentful ID
b8a39b66-c0ef-9cf1-53ff-8267e1339239-draft
Company Values
Entity Description
Developing mobile, scalable, integral nuclear generators with simplified, containerized design.
Entity Name
HolosGen
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
High-temperature, gas-cooled reactors with an closed-loop turbojet combustion system integrated into the core unit, eliminating balance of plant (BoP) components. Dry cooling supports the combined Brayton-organic Rankine power conversion cycle, and Holos Generators are capable of high-resolution, automatic load following. The core is formed through the neutronic coupling of independently subcritical, integral power modules, actively positioned on-site by an Automatic Module Positioning System (AMPS). Entire Holos Quad generators, capable of producing up to 13 MWe without fit inside a single ISO container; the larger Holos Titan generators, housed in 12 ISO containers would be capable of producing up to 81 MWe. A smaller Holos generator for rapid deployment applications (like emergency response) would be configured for air transport and for use as stand-alone electric islands without need for substation switchyard equipment.
Technology Name
Holos Generators

NuGen

Contentful ID
dfd7c13c-6522-e9a4-8d1f-aba4051a104b-draft
Entity Description
A nuclear technology startup founded to develop a fully integrated nuclear-fueled engine concept.
Entity Name
NuGen
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
A advanced, ultra-compact gas-cooled reactor with an energy conversion system and turbomachinery integrated into the core. Initial development efforts for the 3-50 MWe design are focused on remote locations, including space, and critical national security sites.
Technology Name
The NuGen Engine

Yellowstone Energy

Contentful ID
96740e79-0549-db81-1138-44e54c726339-draft
Company Values
Entity Description
Developing an advanced modular nuclear reactor with integrated thermal energy storage
Entity Name
Yellowstone Energy
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
A modular reactor cooled by molten nitrate salt and solid uranium oxide fuel with integrated thermal energy storage
Technology Name
Molten Nitrate Salt Reactor (MNSR)

Micronuclear LLC

Contentful ID
e9331957-e816-18e7-0e53-44d5e0a792c1-draft
Entity Description
A Tennessee-based company pursuing commercialization of its MW-scale nuclear fission "battery". Micronuclear LLC received a GAIN (Gateway for Accelerated Innovation in Nuclear) voucher in 2017 for development work at Idaho National Lab.
Entity Name
Micronuclear LLC
Focus Areas
Entity Type
Company
Is LCRI Company?
No
Technology Description
This simplified molten salt reactor is designed to reduce design and operational complexity: passive heat pipes eliminate the need for heat exchanger tubes and a naturally-circulating primary flow eliminates the need for pumps. Reactor system to be coupled with a small commercial gas turbine for electricity production of ~5 MWe.
Technology Name
Micro-scale Nuclear Battery (MsNB)