Contentful ID
346414493
HolosGen
Contentful ID
b8a39b66-c0ef-9cf1-53ff-8267e1339239-draft
Company Values
Entity Description
Developing mobile, scalable, integral nuclear generators with simplified, containerized design.
Entity Name
HolosGen
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
High-temperature, gas-cooled reactors with an closed-loop turbojet combustion system integrated into the core unit, eliminating balance of plant (BoP) components. Dry cooling supports the combined Brayton-organic Rankine power conversion cycle, and Holos Generators are capable of high-resolution, automatic load following. The core is formed through the neutronic coupling of independently subcritical, integral power modules, actively positioned on-site by an Automatic Module Positioning System (AMPS). Entire Holos Quad generators, capable of producing up to 13 MWe without fit inside a single ISO container; the larger Holos Titan generators, housed in 12 ISO containers would be capable of producing up to 81 MWe. A smaller Holos generator for rapid deployment applications (like emergency response) would be configured for air transport and for use as stand-alone electric islands without need for substation switchyard equipment.
Technology Name
Holos Generators
Japan Atomic Energy Agency (JAEA)
Contentful ID
1d678c9d-a0d1-2a2d-c26c-da81e323604c-draft
Company Values
Entity Description
A Japanese Administrative Institution and Japan's comprehensive nuclear energy research and development institute
Entity Name
Japan Atomic Energy Agency (JAEA)
Focus Areas
General - Organization
Entity Type
Other
Is LCRI Company?
No
Technology Areas
Technology Description
GTHTR300 is a helium-cooled, graphite-moderated thermal spectrum, prismatic high-temperature gas-cooled reactor with 14% enriched uranium-based TRISO fuel with flexible industrial/electricity generation applications. It provides a maximum of 600 MWt power and 100-300 MWe, depending on its application.
Technology Name
Gas Turbine High Temperature Reactor, 300 MW (GTHTR300)
Ultra Safe Nuclear Corporation
Contentful ID
eba05547-fd6b-fb6b-4008-6489368a9c7a-draft
Company Values
Entity Description
a developer of innovative nuclear technologies, including TRISO-based fuels for conventional reactors, "micro-modular" advanced reactors and nuclear thermal propulsion systems
Entity Name
Ultra Safe Nuclear Corporation
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The MMR is a 5 or 10 MWe gas-cooled, graphite-moderated thermal spectrum advanced reactor. It is fueled by Ultra Safe Nuclear Corp.'s own Fully Ceramic Microencapsulated (FCM), TRISO-based fuel and is designed for 20+ years without refueling. In this design, power production, power conversion and electricity generation are integrated into a single factory-fabricated vessel. A service agreement is under development as part of the Canadian Nuclear Safety Commission's Pre-Licensing Vendor Design Review process.
Technology Name
Micro Modular Reactor (MMR)
Hybrid Power Technologies, LLC
Contentful ID
6fbe3782-68fb-55fc-92cf-d096c8207764-draft
Company Values
Entity Description
Pursuing a hybrid natural gas-nuclear method of electricity generation
Entity Name
Hybrid Power Technologies, LLC
Entity Owler ID
5833424
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
This hybrid system produces a peaking power of 850 MWe via a prismatic high-temperature gas reactor coupled to a natural gas-fired facility, enabling rapid load-following. The nuclear system is moderated by graphite and utilizes low-enriched TRISO fuel with a 2-year refueling cycle. An open-system Brayton cycle combustion turbine with a bottoming Rankine steam cycle enables very high thermal efficiencies.
Technology Name
Hybrid Nuclear Advanced Reactor
Framatome (formerly AREVA)
Contentful ID
f44237f9-ba3c-8edd-55b1-a93b3d168b88-draft
Company Values
Entity Description
Framatome is an established French nuclear energy company with operations in France, Germany, China and the United States.
Entity Name
Framatome (formerly AREVA)
Entity Owler ID
136092
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The SC-HTGR is a modular graphite-moderated, helium-cooled high temperature gas-cooled reactor with a prismatic block-type core configuration. This 625 MWt TRISO-fueled reactor is most suitable for industrial applications and may also be used for electricity generation.
Technology Name
Steam-Cycle High Temperature Gas-Cooled Reactor (SC-HTGR)