Contentful ID
4237666130
Anterix Inc.
Contentful ID
6NyWXdg78CQXL3aUrd7Nah
Company Values
Entity Description
Anterix is building the foundation for a new technology landscape. Our mission is to deliver the transformative broadband needed to enable the modernization of critical infrastructure for energy, transportation, logistics, and other industries.
Anterix enables critical infrastructure and enterprises to transform their businesses through the power of private wireless broadband connectivity on 900 MHz spectrum. Our foundational spectrum allows for greater risk mitigation with increased cybersecurity, resiliency, and control. We are the largest holder of licensed spectrum in the 900 MHz band, with nationwide coverage throughout the contiguous United States, Hawaii, Alaska, and Puerto Rico. Anterix has obtained approval by the Federal Communications Commission to modernize and realign the 900 MHz band so it can be used to deploy broadband networks, technologies, and solutions.
Anterix enables critical infrastructure and enterprises to transform their businesses through the power of private wireless broadband connectivity on 900 MHz spectrum. Our foundational spectrum allows for greater risk mitigation with increased cybersecurity, resiliency, and control. We are the largest holder of licensed spectrum in the 900 MHz band, with nationwide coverage throughout the contiguous United States, Hawaii, Alaska, and Puerto Rico. Anterix has obtained approval by the Federal Communications Commission to modernize and realign the 900 MHz band so it can be used to deploy broadband networks, technologies, and solutions.
Entity Name
Anterix Inc.
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Pilots/Demonstrations
Technology Areas
Technology Description
Anterix has licensed a portion ofthe900 MHz spectrum for a private broadband network for utilities –Private LTE(“PLTE”).Asthe largest owner of 900 MHz spectrum, they working with FCC to make the spectrum usable for broadband networks (3x3 MHz).Anterix is not creating new spectrum, but through re-organization of a portion of the band and the existing users, and coordinating rules changes with the FCC, it becomes possible to open enough contiguous spectrum to support private LTE.LTE itself is a mature technology, so the Anterix spectrumcan leverage existing communications hardware while also being an enabler for private utility networksthat can offer improved reliability and security over public LTE networks.Anterix’s “LTE-in-a-box” offering is an all-inclusive software implementation of LTE core elements and the LTE radio access network (eNB) functions, whichcan be implemented as a private network thatallows equipment with appropriate USIM cards to attach on the 900 MHz (Band 8) spectrum.
Technology Name
PLTE
Los Alamos National Laboratory
Contentful ID
f1a40c2f-36d0-f5eb-1dc1-bd17fd839fc2-draft
Company Values
Entity Description
A United States Department of Energy national laboratory located in New Mexico.
Entity Name
Los Alamos National Laboratory
Focus Areas
General - Organization
Entity Type
National Lab
Is LCRI Company?
No
Technology Areas
Technology Description
A 5 MWt/2 MWe heat pipe reactor for "plug-and-go" power applications in remote installations and communities. The design is capable of rapid installation and shutdown and largely autonomous operation for 5 years without refueling. MegaPower is fueled by high-assay low enriched uranium oxide.
Technology Name
MegaPower/Special Purpose Reactor
X-Energy
Contentful ID
806b7d1a-b46b-515a-7b7b-4929cad1f7fd-draft
Company Values
Entity Description
X-Energy was formed to develop and commercialize its pebble bed high temperature gas-cooled reactor design. The company is also developing and has plans to manufacture TRISO fuel pebbles.
Entity Name
X-Energy
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The X-battery is a gas-cooled pebble bed reactor fueled by high assay LEU fuel particles, capable of autonomous operation. The 10 MWt reactor is road-transportable and can be configured to provide combined heat and power.
Technology Name
X-battery / Xe-100 MICRO reactor
Seaborg Technologies
Contentful ID
2771f9cd-7832-e746-ab4b-16e8f8fa650b-draft
Company Values
Entity Description
Seaborg is a Danish company developing a thorium MSR concept.
Entity Name
Seaborg Technologies
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The CUBE is a 150 MWt/100 MWe liquid-fueled, single fluid, thermal spectrum molten salt reactor design fueled by a combination of thorium and spent fuel from LWRs.
Technology Name
Seaborg CUBE (Compact Used fuel BurnEr) reactor
Westinghouse Electric Company, LLC
Contentful ID
2e676575-4bde-0b4c-d1ad-382d4c41216a-draft
Company Values
Entity Description
Westinghouse Electric is a nuclear technology company that offers nuclear plant design, fuel service and maintenance and control systems solutions.
Entity Name
Westinghouse Electric Company, LLC
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
Scalable, heat pipe-cooled reactor design producing combined heat and power of 0.2-25 MWe for decentralized and/or remote generation markets. The factory-built and assembled eVinci has inherent load following capabilities, rapid on-site installation potential, and infrequent refueling needs.
Technology Name
eVinci Micro Reactor
NuGen
Contentful ID
dfd7c13c-6522-e9a4-8d1f-aba4051a104b-draft
Company Values
Entity Description
A nuclear technology startup founded to develop a fully integrated nuclear-fueled engine concept.
Entity Name
NuGen
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
A advanced, ultra-compact gas-cooled reactor with an energy conversion system and turbomachinery integrated into the core. Initial development efforts for the 3-50 MWe design are focused on remote locations, including space, and critical national security sites.
Technology Name
The NuGen Engine
Yellowstone Energy
Contentful ID
96740e79-0549-db81-1138-44e54c726339-draft
Company Values
Entity Description
Developing an advanced modular nuclear reactor with integrated thermal energy storage
Entity Name
Yellowstone Energy
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
A modular reactor cooled by molten nitrate salt and solid uranium oxide fuel with integrated thermal energy storage
Technology Name
Molten Nitrate Salt Reactor (MNSR)
Micronuclear LLC
Contentful ID
e9331957-e816-18e7-0e53-44d5e0a792c1-draft
Company Values
Entity Description
A Tennessee-based company pursuing commercialization of its MW-scale nuclear fission "battery". Micronuclear LLC received a GAIN (Gateway for Accelerated Innovation in Nuclear) voucher in 2017 for development work at Idaho National Lab.
Entity Name
Micronuclear LLC
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
This simplified molten salt reactor is designed to reduce design and operational complexity: passive heat pipes eliminate the need for heat exchanger tubes and a naturally-circulating primary flow eliminates the need for pumps. Reactor system to be coupled with a small commercial gas turbine for electricity production of ~5 MWe.
Technology Name
Micro-scale Nuclear Battery (MsNB)
Westinghouse Electric Company LLC
Contentful ID
9f401e4a-6d53-606b-3cbe-75f8678ffd83-draft
Entity Description
A Pennsylvania-based nuclear energy company providing a range of services to the nuclear industry, including fuels, instrumentation and control design, plant service and maintenance, and reactor design.
Entity Name
Westinghouse Electric Company LLC
Focus Areas
General - Organization
Entity Type
Company
Group/Division/Lab name
Nuclear Energy
Is LCRI Company?
No
Technology Areas
Technology Description
The Westinghouse LFR is a lead-cooled, fast spectrum reactor with an output in the 500 MWe range.
Technology Name
Westinghouse lead-cooled fast reactor
Tsinghua University
Contentful ID
3dbdd9d2-b722-96bb-3495-5c6b9be8d736-draft
Company Values
Entity Description
Conducts research and development in science, technology, engineering and demonstration in the fields of energy, environment and natural resources
Entity Name
Tsinghua University
Focus Areas
General - Organization
Entity Type
University
Group/Division/Lab name
Institute of Nuclear and New Energy Technology
Is LCRI Company?
No
Technology Areas
Technology Description
HTR-PM is a helium-cooled, graphite-moderated thermal spectrum reactor with a pebble bed core. With 8.5% enriched uranium-based TRISO fuel, this reactor has a capacity of 250 MWt/105 MWe. A two-unit demonstration plant is in the final stages of construction, and is expected to come online this year.
Technology Name