Contentful ID
1158252132
X-Energy
Contentful ID
806b7d1a-b46b-515a-7b7b-4929cad1f7fd-draft
Company Values
Entity Description
X-Energy was formed to develop and commercialize its pebble bed high temperature gas-cooled reactor design. The company is also developing and has plans to manufacture TRISO fuel pebbles.
Entity Name
X-Energy
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The X-battery is a gas-cooled pebble bed reactor fueled by high assay LEU fuel particles, capable of autonomous operation. The 10 MWt reactor is road-transportable and can be configured to provide combined heat and power.
Technology Name
X-battery / Xe-100 MICRO reactor
Tsinghua University
Contentful ID
3dbdd9d2-b722-96bb-3495-5c6b9be8d736-draft
Company Values
Entity Description
Conducts research and development in science, technology, engineering and demonstration in the fields of energy, environment and natural resources
Entity Name
Tsinghua University
Focus Areas
General - Organization
Entity Type
University
Group/Division/Lab name
Institute of Nuclear and New Energy Technology
Is LCRI Company?
No
Technology Areas
Technology Description
HTR-PM is a helium-cooled, graphite-moderated thermal spectrum reactor with a pebble bed core. With 8.5% enriched uranium-based TRISO fuel, this reactor has a capacity of 250 MWt/105 MWe. A two-unit demonstration plant is in the final stages of construction, and is expected to come online this year.
Technology Name
High Temperature Gas-cooled Reactor, Pebble-bed Module (HTR-PM)
StarCore Nuclear
Contentful ID
6ce5a382-f9ad-5002-2680-c9d152ecc378-draft
Company Values
Entity Description
StarCore Nuclear is developing and commercializing its small, fully factory-fabricated and truck bed-deliverable high temperature gas reactor designed for remote, off-grid locations and for operation under a Power Purchase Agreement-based business model.
Entity Name
StarCore Nuclear
Entity Owler ID
6682599
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The StarCore SPB is a 36 MWt/20 MWe helium-cooled, graphite moderated high temperature gas reactor. The standard TRISO fuel pebbles are static in the core, and the reactor operates for 5 years without refueling. A service agreement is currently under development through the Canadian Nuclear Safety Commission's Pre-Licensing Vendor Design Review process.
Technology Name
StarCore Static Pebble Bed Reactor (StarCore SPB)
X-Energy, LLC
Contentful ID
d0ad114c-54dd-c41b-0a49-5988ad314440-draft
Company Values
Entity Description
X-Energy was formed to develop and commercialize its pebble bed high temperature gas-cooled reactor design. The company is also developing and has plans to manufacture TRISO fuel pebbles.
Entity Name
X-Energy, LLC
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The Xe-100 is a helium-cooled, graphite-moderated high temperature gas reactor operating in an epithermal neutron spectrum with a pebble bed fuel configuration. It utilizes TRISO fuel pebbles, based on 15.5% enriched uranium and produces 200 MWt/76 MWe.
Technology Name
Xe-100