Contentful ID
912140382

Massachusetts Institute Of Technology (MIT)

Contentful ID
af462ab6-7620-51a4-2d72-be8ca8b57846-draft
Company Values
Entity Description
Massachusetts Institute Of Technology is an educational institution that offers various degree programs in technology and engineering.
Entity Name
Massachusetts Institute Of Technology (MIT)
General - Organization
Entity Type
University
Group/Division/Lab name
Department of Mechanical Engineering
Is LCRI Company?
No
Technology Description
A dispatchable, grid-scale thermal energy storage system based on a molten silicon storage medium. Excess electricity is converted to thermal energy to heat the silicon, stored in one of two large tanks. When demand arises, glowing-hot molten silicon is pumped through an array tubes that emit light, and special-purpose multi-junction photovoltaics convert the generated light to electricity.
Technology Name
Thermal Energy Grid Storage-Multi-Junction Photovoltiacs (TEGS-MPV) / "Sun in a Box"

SolarWindow Technologies, Inc.

Contentful ID
9d2c77c2-cb77-dce8-eccf-83763d9fbc19-draft
Company Values
Entity Description
Solar Window designs and manufactures electricity-generating see-through windows and glasses for detached homes and commercial buildings.
Entity Name
SolarWindow Technologies, Inc.
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Description
SolarWindow's organic photovoltaic arrays (OPVs) modules are created by applying ultra-thin liquid polymer coatings to glass and flexible plastics. The modules can
Technology Name
SolarWindow

Brayton Energy, LLC

Contentful ID
7e23773d-520f-fc94-6e45-1470e635eccc-draft
Company Values
Entity Description
Brayton Energy designs and manufactures turbine, heat exchangers and turbomachinery for thermal power plants.
Entity Name
Brayton Energy, LLC
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The Brayton Energy team will develop an energy storage system that combines thermal storage and a gas turbine to generate power. When the system is charging, an electrically driven heat pump will accumulate thermal energy in a molten salt solution, which can then be discharged later by heating gas and sending it through the generation turbine. Brayton Energy’s innovation lies in their reversible turbine design, in which each turbine acts as the compression stage for the other, whether during charging or discharging. This approach simplifies the system and increases durability.
Technology Name
Improved Laughlin-Brayton Cycle Energy Storage