Contentful ID
3291409133
Gravity Power, LLC
Contentful ID
31a50fb4-d52e-0d46-9630-d3b66f061853-draft
Company Values
Entity Description
Developing underground, pumped-hydro based energy storage technology.
Entity Name
Gravity Power, LLC
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
GPM technology circumvents the traditional PSH difficulties associated with siting, negative environmental impact, huge land demands, permitting, long-lead times and the very large investment required.
Technology Name
Gravity Power Module(GPM)
QUIDNET ENERGY
Contentful ID
c0986633-dac5-f6d1-c3e8-e8dfd06394e2-draft
Company Values
Entity Description
Quidnet operates at the nexus of energy and water to provide cost-effective, grid-scale electricity storage. This enables predictable delivery of power from intermittent sources and large-scale deployment of renewable energy.
Entity Name
QUIDNET ENERGY
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
Quidnet Energy pioneered a novel form of pumped hydro that is widely deployable at very low cost called Flex Formation Subsurface Pumped Hydro. Leveraging mature oil & gas technology, wells are converted into energy storage facilities for large-scale renewables integration and grid management.
As part of ARPA-E (DAYS) program, the Quidnet Energy team will develop a modified pumped hydro energy storage system using rocks beneath the Earth’s surface. The team will pump pressurized water into gaps in underground rocks. When energy is needed later, the induced strain in the surrounding rock will force water back through a generator to produce electricity.
As part of ARPA-E (DAYS) program, the Quidnet Energy team will develop a modified pumped hydro energy storage system using rocks beneath the Earth’s surface. The team will pump pressurized water into gaps in underground rocks. When energy is needed later, the induced strain in the surrounding rock will force water back through a generator to produce electricity.
Technology Name
Geomechanical Pumped Storage
Max Boegl Wind
Contentful ID
27214562-4fad-35da-4461-5edbee99dff1-draft
Company Values
Entity Description
Construction company with deep expertise in tall wind turbines.
Entity Name
Max Boegl Wind
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The "Water Battery" is conventional pumped hydro storage (PHS) co-located with high hub-height wind turbines. The upper reservoir of the PHS is built at the base of the towers.
Technology Name
"Water Battery"
Heindl Energy
Contentful ID
c3fcb71d-7a26-0f2b-aa40-087cfd463d55-draft
Company Values
Entity Description
Technology developer for "Gravity Storage" bulk energy storage concept.
Entity Name
Heindl Energy
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
Energy is stored by pumping water into a purpose-built subsurface cavern that sits beneath a giant rock cylinder. The pumped water is held at pressure by the weight of the rock.
Technology Name
"Gravity Storage"