Contentful ID
3998852700
Tu Delft
Contentful ID
b4390051-fd18-defe-cc24-976650f5873f-draft
Company Values
Entity Description
Tu Delft is a public technical university based inĀ Netherlands.
Entity Name
Tu Delft
Entity Owler ID
247121
Focus Areas
General - Organization
Entity Type
University
Group/Division/Lab name
Prof. Fokko Mulder
Is LCRI Company?
No
Technology Areas
Technology Description
Combines Electricity Storage And Hydrogen Production In A Single System, The battolyser is based on the 'nickel-iron battery', a type promoted in the twentieth century particularly by Thomas Edison. Mulder commented, 'It's a very robust battery. Original examples are still working. Also, the raw materials are cheap and obtainable anywhere.' While the battery is charging, the electrodes produce two materials (NiOOH and reduced Fe), which are familiar in the world of electrolysis as a catalyst for the chemical reaction that produces hydrogen and oxygen. Thus, the electrodes, in their charged state, enable water to be electrolysed.
Technology Name
Battolyser
Nano Hydro Chem
Contentful ID
d1a098ce-defd-20cb-469d-88e3ff5636ef-draft
Entity Description
Nanomaterial capable of generating hydrogen gas from water on demand, at room temperature
Entity Name
Nano Hydro Chem
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Delft University of Technology
Contentful ID
0db82c4f-cda7-c39f-d0e6-73c3da428eb8-draft
Entity Description
The research focus is on the fundamental and practical aspects of energy storage and conversion materials for renewable energy applications. The overall goal is to study materials and methods that can contribute to the large scale implementation of renewable energy storage, and with that can enable large scale introduction of varying renewable energy sources. The materials studied include hydrogen storage materials, battery materials and electrolytes. The fundamental aspects studied include the physical effects of nanostructuring, the reversibility of hydrogen and lithium storage materials, electrochemical reactions, and in general factors that enable efficient and durable functioning of the materials.
Entity Name
Delft University of Technology
Focus Areas
General - Organization
Entity Type
University
Group/Division/Lab name
Mulder Group
Is LCRI Company?
No
Technology Areas
Technology Description
Combines electricity storage and hydrogen production in a single system, enabling electricity to be stored efficiently and affordably
Technology Name
Battolyser